Delta Amplon INX-2K online UPS, Standard Runtime (internal battery)
2 kVA (2000 VA); 1600 W or 1800 W depending on version, as shown on the rating label
True online double conversion; zero transfer time; pure sine wave output
Internal battery: 4 x 12V 9Ah, 48V DC
Efficiency: 89% (online mode)
Cold start; overload, short circuit, over-temperature and low battery protection
USB and RS-232; mini slot for optional SNMP card
4 x India sockets

₨ 53,500.00 53500.0 NPR ₨ 53,500.00

₨ 53,500.00


    This combination does not exist.

    Add to Cart


    • 100% original products
    • VAT bill provided · 13% VAT included
    • Delivery all over Nepal in 2 to 5 daysFree within 15 km on products over Rs 5,000
    • Secure online payment · connectIPS

    Share :

    Delta Amplon INX-2K 2KVA/48V Online UPS price in Nepal

    The Delta Amplon INX-2K 2KVA/48V Online UPS costs Rs 53,500 at Quality Computer.

    Prices on this page update automatically when they change.

    See all: UPS Price in Nepal 2026

    This Delta online UPS is the Amplon INX-2K Standard Runtime Model: a 2 kVA true online double-conversion UPS with four 12 V / 9 Ah batteries built in (48 Vdc). Delta gives zero transfer time to battery and a pure sine wave output in battery mode. It has four India sockets and USB and RS-232 ports. Delta India lists two versions of it on two pages: the original "INX Series" (1600 W) and the "INX Series (CE Certification)" (1800 W). Where their figures differ, this page marks them "original" and "CE version". The rating label on the UPS shows which one it is; ask us which rating the unit you're buying has.

    Delta INX-2K highlights

    • True online double-conversion UPS with zero transfer time to battery; pure sine wave output in battery mode.
    • 2 kVA: 1600 W on the original INX-2K (power factor 0.8), 1800 W on the CE version (power factor 0.9).
    • Four 12 V / 9 Ah batteries built in (48 Vdc). There's no external battery connector.
    • Efficiency 89% in online mode. Delta gives 94% in ECO mode for the CE version.
    • Backup time on the CE version: 22.4 minutes at 450 W, 9.8 minutes at 900 W, 5.5 minutes at 1350 W and 3.0 minutes at 1800 W.
    • Cold start (it can start on battery power when the mains is out) and ECO mode. Delta's original INX page and manual also list automatic bypass on overload or internal fault, and a frequency converter mode.
    • Four India sockets, an LCD screen, USB and RS-232 ports, and a mini slot for Delta's optional SNMP, Modbus or relay I/O cards.
    • Over-voltage and battery deep-discharge protection. Delta's original INX page and manual also list protection against overload, output short circuit, over-temperature and high or low battery voltage.

    Who the Delta INX-2K is for

    A good fit if you need a 2 kVA online UPS with batteries built in for short power cuts, and your equipment draws no more than 1600 W (1800 W on the CE version).

    Look at something else if you need long backup. The built-in batteries give 5.5 minutes at 75% load on the CE version, and there's no connector for extra batteries. Delta's Extended Runtime INX-2K models run at 72 Vdc and use external battery banks.

    Buying from Quality Computer

    Delta India lists two versions of this internal-battery INX-2K: the original INX, rated 2000 VA / 1600 W, and the CE-certified INX, rated 2000 VA / 1800 W. Our listing gives 1600 W. The rating label on the UPS shows which one it is; ask us before you buy.

    Monitoring is by USB or RS-232 (Delta says they can't be used at the same time). Web or network monitoring needs Delta's optional mini SNMP card in the mini slot; ask us if you need one.

    Our listing includes a 24-month warranty on the UPS and 12 months on the batteries.

    Delta INX-2K specifications

    ModelDelta Amplon INX-2K, Standard Runtime Model (internal battery)
    TypeTrue online double conversion; zero transfer time to battery
    Rating2000 VA / 1600 W, power factor 0.8 (original INX); 2000 VA / 1800 W, power factor 0.9 (CE version). Ask us which version
    Output waveformPure sine wave (battery mode)
    Input voltage230 Vac nominal. Original: 110–300 Vac (Delta India page; manual 110–285 Vac), load de-rated to 60–100% at 110–160 Vac. CE version: 180–285 Vac at full load, down to 120 Vac with load de-rated to 60–100%
    Input frequency40–70 Hz
    Input power factor> 0.99 (CE version: at full load)
    Input plug10 A India plug (original, Delta's manual); 16 A India plug (CE version)
    Output voltage200, 208, 220, 230 or 240 Vac; ±1% in battery mode. Original: de-rated to 80% capacity at 200 or 208 Vac. CE version: 30% de-rating at 208 Vac
    Output frequencyOriginal: synchronised 47–53 Hz or 57–63 Hz; battery mode 50 Hz ±0.25 or 60 Hz ±0.3. CE version: 50/60 ±3 Hz
    Harmonic distortion≤ 3% with linear load; ≤ 6% with non-linear load (original)
    Overload< 105% continuous; 105–110% for 10 minutes; 110–130% for 1 minute; > 130% for 3 seconds
    Crest factor3:1
    EfficiencyOnline (AC) mode 89%; ECO mode 94% (CE version; Delta gives no ECO figure for the original)
    Batteries4 × 12 V / 9 Ah, 48 Vdc, built in (Delta's manual); VRLA (CE leaflet); no external battery connector
    Backup time (CE version)22.4 min at 450 W; 9.8 min at 900 W; 5.5 min at 1350 W; 3.0 min at 1800 W
    Charge current1 A
    Recharge time4 hours to 90% capacity, typical (Delta's manual)
    Battery life3 to 5 years at 25 °C ambient (Delta's manual)
    Output sockets4 × India sockets
    DisplayLCD screen with three multi-function buttons (original); LCD screen with LED indicators (CE version)
    CommunicationUSB and RS-232 (not at the same time, per Delta's manual); 1 mini slot for optional mini SNMP, Modbus or relay I/O cards (the manual also lists TVSS cards)
    ProtectionOver-voltage and battery deep discharge; overload, output short circuit, over-temperature, high or low battery voltage and charger failure (Delta's manual)
    Other featuresCold start on battery and ECO mode; automatic bypass on overload or internal fault, frequency converter mode and fan speed control (original INX page and Delta's manual)
    Audible alarmsBattery mode, low battery, overload, fault, bypass mode (CE version)
    Size145 × 504 × 220 mm (W × D × H)
    Weight16.5 kg (original); 16.8 kg (CE version)
    Noise< 50 dB at 1 m (original); < 45 dBA at under 75% load, 25 °C, online mode (CE version)
    Operating temperature0–40 °C (original); 0–50 °C, de-rated to 70% load at 40–50 °C (CE version)
    Humidity20–90% RH, non-condensing
    CertificationsSafety: BIS, CE; EMC: IEC 62040-2 (both versions)
    In the boxUPS, input cable, USB cable, user manual (Delta's manual)
    WarrantyUPS 24 months; battery 12 months (our listing)

    Delta INX-2K questions

    Is it 1600 W or 1800 W?

    It depends on the version. Delta India's original INX-2K and Delta's 2022 user manual give 2000 VA / 1600 W (power factor 0.8). Its CE-certified INX version is 2000 VA / 1800 W (power factor 0.9). The rating label on the UPS shows which one it is; ask us before you buy.

    How long will the batteries run my equipment?

    Delta's leaflet for the CE version gives 22.4 minutes at 450 W, 9.8 minutes at 900 W, 5.5 minutes at 1350 W and 3.0 minutes at 1800 W. Delta doesn't give backup times for the original version. Its manual gives a typical recharge time of 4 hours to 90% capacity.

    Can I monitor it over the network?

    Not out of the box. It has USB and RS-232 ports, which Delta says can't be used at the same time, and a mini slot. Network or web monitoring needs Delta's optional mini SNMP card in that slot.

    Can I change the batteries myself?

    Delta's manual says the UPS has no user-serviceable parts and asks you to contact your dealer to replace the batteries. Delta gives a battery life of 3 to 5 years at 25 °C. Ask us when they need replacing.

    For this 2 kVA model Delta gives 89% in online mode (both versions) and 94% in ECO mode (CE version). The higher "up to" figures on Delta's series pages (90% online, 97% in ECO mode) are for the INX range as a whole, not this model.

    Delta's manual and its CE version page give the size as 145 mm wide, 504 mm deep and 220 mm high. Delta India's original INX page prints the same figures as 504 × 145 × 220 mm and labels them W × D × H.

    Backup times are from Delta's leaflet for the CE (1800 W) version.

    Automatic bypass, frequency converter mode, fan speed control and the protections other than over-voltage and deep discharge come from Delta India's original INX page and Delta's manual. The CE version's page lists cold start, ECO mode, over-voltage and deep-discharge protection, and a bypass-mode alarm.

    Specifications checked against Amplon INX series 1–3 kVA single-phase UPS (Delta Electronics India), Amplon INX series 1–3 kVA, CE certification (Delta Electronics India), Amplon INX Series II 1–3 kVA user manual, May 2022 (Delta) and Amplon INX 1–3 kVA leaflet, CE version (Delta India) on 4 November 2026.